RUO

    For laboratory research use only. Not for human or veterinary consumption. Not a drug, food, or dietary supplement. Not for diagnostic or therapeutic use.

    Reference & sourcing standards

    Research. With clarity.

    Independent reference data and sourcing standards for laboratory research peptides.

    For laboratory research use only. Not for human or veterinary consumption. Not a drug, food, or dietary supplement. Not for diagnostic or therapeutic use.

    • Research use only
    • 7-point testing, every batch
    • Batch records retained
    • Evidence before checkout

    Procurement criteria

    What separates a documented supplier

    Three records determine whether a supply claim can be checked: the analytical data, the certificate that binds it to a batch, and the custody trail behind the batch.

    01

    Third-party HPLC and mass-spec verification

    Purity is a method-dependent number. A figure reported without the analytical conditions behind it cannot be compared across suppliers. Reverse-phase HPLC separates a sample into its components and reports the main peak as a share of total integrated peak area; the result shifts with column chemistry, gradient, flow rate, and detection wavelength.

    Mass spectrometry answers a different question. It confirms that the material eluting at the expected retention time carries the expected mass, within instrument tolerance. Purity without identity confirmation tells you a sample is homogeneous, not that it is the stated compound.

    Third-party execution matters because the laboratory performing the assay has no interest in the release decision. Records on this site state the testing laboratory, the instrument class, the method parameters, and the date of analysis, so a procurement reviewer can reproduce the comparison rather than accept a summary figure.

    Testing methodology →

    02

    Batch-linked certificates of analysis

    A certificate of analysis describes one batch. It is not a property of a catalogue listing, and a certificate that carries no batch identifier cannot be tied to the vial in front of you. Each record published here is keyed to a batch identifier printed on the container label, so the document and the material can be matched at receipt.

    A usable certificate states the analyte, the batch, the test methods, the acceptance specification, the observed result, the analysis date, and the laboratory that produced it. Chromatograms and mass spectra are retained alongside the summary sheet rather than replaced by it.

    Where a batch has been retested or re-released, the prior record remains available. Documentation that only shows current results conceals the history a reviewer needs. Superseded certificates are marked, not removed.

    Certificate archive →

    03

    Chain-of-custody documentation

    Analytical data describes a sample. Chain-of-custody describes what happened to the material between synthesis and delivery, and it is the part of a supply record that most often goes unpublished.

    The records referenced here track synthesis site qualification, lyophilisation and fill date, container and closure type, storage temperature during holding, transfer points between facilities, and the conditions under which shipments left the warehouse. Each transfer is logged with a date and a responsible party.

    This matters because storage and transit conditions affect a peptide independently of how it was made. A batch released at high purity can degrade before it reaches a bench if it was held outside its stated temperature range. Sourcing criteria applied to our supply partner, including qualification requirements and audit frequency, are published in full rather than summarised.

    Sourcing standards →

    Explainer

    How to read a certificate of analysis

    A certificate is a record of one batch tested by one method on one date. Four fields carry most of the information. The specimen below is annotated; the values are illustrative.

    CERTIFICATE OF ANALYSIS — SPECIMENBATCH FA-2602-01630.020.0 minmAU1 · RETENTION TIME11.42 min — elution position under the statedcolumn, gradient, and flow-rate conditions.2 · PEAK AREAIntegrated response for the main peak,reported against total integrated area.RESULTVALUEPurity (RP-HPLC, 214 nm)98.6 %Observed mass (ESI-MS)567.7 DaTheoretical mass567.64 Da3 · PURITY PERCENTAGEMain-peak area divided by total peak area,at the stated detection wavelength. A purityfigure without a method and wavelength isnot interpretable.4 · IDENTITY CONFIRMATIONObserved mass compared against the theoreticalmonoisotopic mass of the stated sequence.

    1 · Retention time

    The elution position of the main peak, in minutes, under the stated column, gradient, and flow-rate conditions. Reported alone it means little; compared against a reference standard run on the same method it is a first identity check. A retention time quoted without method conditions is not verifiable.

    2 · Peak area

    The integrated detector response for a peak. Purity is derived from area, not peak height, so the integration parameters and the baseline treatment affect the outcome. Certificates that publish the chromatogram allow the integration to be inspected; certificates that publish only a percentage do not.

    3 · Purity percentage

    Main-peak area as a share of total integrated peak area at a stated wavelength, typically 214 nm for peptide bonds. The same batch can report different figures at 214 nm and 280 nm. Always read the wavelength and the method before comparing two suppliers' numbers.

    4 · Identity confirmation

    Observed mass from ESI-MS or MALDI-TOF compared against the theoretical monoisotopic mass of the stated sequence, with the tolerance recorded. Without this line, a certificate establishes only that a sample is homogeneous — not what the sample is.

    Read the complete COA guide →

    Documentation updates

    Batch documentation updates and new reference entries.

    One list. Sent when a certificate archive is updated or a compound record is added. No promotional content.

    Supplier

    Batch records referenced here are hosted on the supplier catalog.

    Certificates and batch documentation for the compounds indexed on this site are hosted on the supplier's catalog pages. Availability and ordering are handled there.

    For laboratory research use only. Not for human or veterinary consumption. Not a drug, food, or dietary supplement. Not for diagnostic or therapeutic use.